Because of our high-strength cast aluminium frames, we can offer you reliable thickness gauges with scale division 0.01 mm: our series DMH. In unoperated position, the measuring calliper is closed and can be opened by means of a lifting lever.

You can also decide whether your thickness gauge shall have a foot or not. We recommend the option with foot in order to reduce measurement errors due to body warmth to a minimum.

You may get these thickness gauges also in digital display as series DMD. Beside of a change-over switch mm/in the digital variants can optionally be delivered with an interface for the digital processing of the measuring values.

For leather, fleece and textiles there are special models. According to the applicable regulations, these special models apply the prescribed test pressures to a specified circular calliper surface. In order to ensure the test pressure, these devices are offered only with foot.
Overview analogous thickness gauges series DMH
  Standard version According to the test standard for...
Type Measuring range
in mm
Measuring depth
in mm
scale division
in mm
Item no.
mit foot
Item no.
without foot
Leather
50 kPa on 0,785 cm²
Fleece
0,5 kPa on 25 cm²
Textiles
1,0 kPa on 20 cm²
DMH 3 0 ‒ 10 50 0.01 521 31# 520 31# 521 31L 521 31V 521 31T
DMH 3/1 0 ‒ 25 50 0.01 521 32# 520 32# 521 32L 521 32V 521 32T
DMH 820 0 ‒ 10 200 0.01 521 33# 520 33# 521 33L 521 33V 521 33T
DMH 820/1 0 ‒ 25 200 0.01 521 34# 520 34# 521 34L 521 34V 521 34T
DMH 830 0 ‒ 10 300 0.01 521 35# 520 35# 521 35L 521 35V 521 35T
DMH 830/1 0 ‒ 25 300 0.01 521 36# 520 36# 521 36L 521 36V 521 36T
DMH 850 0 ‒ 10 500 0.01 521 50# 521 50L 521 50V 521 50T
DMH 850/1 0 ‒ 25 500 0.01 521 51# 521 51L 521 51V 521 51T
Please replace the hash # in the item number with the code letter of the required gauging insert in dependence on the material to be measured.

You need even larger measuring ranges or measuring depths? Then have a look at our thickness gauges series ”Modul“!